NIC® PTF+ Rotary Glide Path File

NIC® PTF+ Rotary Glide Path File

13/.02 / 21 mm
$42.00 CAD
Sale price  $42.00 CAD Regular price 
Skip to product information
NIC® PTF+ Rotary Glide Path File
MaxTech™ 3.0 Heat Treatment
360° Rotary Motion
Sterilizable 134° C
NiTi Aloy
Detailed product information

Specifications, clinical guidance, documents and safety information are available below.

View product details

NIC® PTF+ Rotary Glide Path File

$42.00 CAD
Sale price  $42.00 CAD Regular price 
Size
Length
In stock
Free Shipping For All Products

We will work quickly to ship your order as soon as possible. All orders ship free with no minimum order quantity. Express shipping is available for an additional fee.

Return Policy

Return eligible items within 30 days of delivery. We offer free returns, making the process simple and hassle-free.

To be eligible for a return, your item must be unused, unopened, in the same condition as received, and in its original packaging. You'll also need the receipt or proof of purchase.

30-Day Try-It Guarantee

Trying one of our endodontic file systems for the first time? We want you to purchase with confidence. If the system is not well suited to your clinical technique, contact us within 30 days of purchase. We will help you select a more suitable option or provide an exchange or refund in accordance with our return policy.

Applies to first-time purchases of eligible products. Maximum one opened pack per product system. Proof of purchase is required.

Product details

NIC® PTF+ Rotary Glide Path File at a glance

Core specifications organized for quick review before selecting a configuration.

Manufacturer NIC® Dental
Motion Continuous clockwise rotation
Heat treatment MaxTech™ 3.0 gold heat-treated NiTi alloy
Cross-section Symmetrical square · four cutting edges
Sizes 13/.02 / 16/.02 / 19/.02
Lengths 21 mm / 25 mm / 31 mm
Packaging 6 instruments / pack
Sterility Non-sterile · sterilize before first use
Product overview

About this product

Additional information about this product and its intended clinical application.

NIC® PTF+ Rotary Glide Path Files are MaxTech™ 3.0 gold heat-treated NiTi instruments designed for mechanical glide-path preparation in continuous clockwise rotation. The three-file sequence includes 13/.02, 16/.02, and 19/.02 sizes in 21 mm, 25 mm, and 31 mm lengths. Supplied non-sterile in packs of 6 for single use; sterilize before first clinical use according to the current manufacturer instructions for use.

File identification

Recognize the file family by colour and size

Identify each file by its size, taper, colour and available length.


                      NIC® PTF+ Rotary Glide Path File
                      PTF+ #1 / P1
                      13/.02
                      Purple
                      file

PTF+ #1 / P1

13/.02
Purple

First mechanical glide-path instrument used to enlarge a smooth, reproducible manual pathway to working length.

21 mm / 25 mm / 31 mm 300 RPM 0.6–1.0 N·cm

                      NIC® PTF+ Rotary Glide Path File
                      PTF+ #2 / P2
                      16/.02
                      White
                      file

PTF+ #2 / P2

16/.02
White

Second instrument used to progressively enlarge the established glide path to working length before canal shaping.

21 mm / 25 mm / 31 mm 300 RPM 0.6–1.0 N·cm

                      NIC® PTF+ Rotary Glide Path File
                      PTF+ #3 / P3
                      19/.02
                      Yellow
                      file

PTF+ #3 / P3

19/.02
Yellow

Optional third instrument used when a larger expanded glide path is clinically required before canal shaping.

21 mm / 25 mm / 31 mm 300 RPM 0.6–1.0 N·cm
Familiar workflow

Coming from PathFile®?

NIC® PTF+ Rotary Glide Path File is organized around a familiar continuous clockwise rotation workflow for clinicians who already use PathFile®. Product-specific specifications and manufacturer guidance remain the reference for clinical use.

  • File family: PTF+ #1 / P1 · PTF+ #2 / P2 · PTF+ #3 / P3
  • Sizes: 13/.02 / 16/.02 / 19/.02
  • Motion: Continuous clockwise rotation
  • Motor program: Continuous rotary · torque-controlled
Motion Continuous clockwise rotation
File family PTF+ #1 / P1 · PTF+ #2 / P2 · PTF+ #3 / P3
Motor setup Continuous rotary · torque-controlled
Heat treatment MaxTech™ 3.0 gold heat-treated NiTi alloy

PathFile® is referenced to help identify a familiar clinical workflow. Product-specific use should follow the current manufacturer instructions for use. Motor terminology can vary between manufacturers.

Clinical specifications

Design & clinical use

Key technical and clinical characteristics of NIC® PTF+ Rotary Glide Path File.

Material / treatment MaxTech™ 3.0 gold heat-treated NiTi alloy
Motion Continuous clockwise rotation
Cross-section Symmetrical square · four cutting edges
Taper design Constant .02 taper
Technique Three-file mechanical glide-path preparation before shaping
Motor & motion

Continuous clockwise rotation motor setup

Recommended operating configuration for this file system.

Motion Continuous clockwise rotation
Motor program Continuous rotary · torque-controlled
Speed 300 RPM
Torque 0.6–1.0 N·cm
Use the motor program and settings specified for this product. If your motor uses different terminology, confirm the selected program and follow the current manufacturer instructions for use.
Clinical workflow

Step-by-step clinical workflow

Follow the clinical sequence below together with the current manufacturer instructions for use.

0 1 Evaluate the canal and create straight-line access Radiographs · access · irrigation

Review pre-operative radiographs to assess canal width, length, visibility and curvature. Create straight-line coronal and radicular access, then irrigate the pulp chamber and canal system.

0 2 Scout the canal and establish a manual glide path ISO 008–010 stainless-steel K-files

Scout the canal with small stainless-steel hand files. Determine working length using an apex locator with radiographs, confirm patency, and establish a smooth, reproducible manual glide path before introducing PTF+.

0 3 Advance PTF+ #1 / P1 to working length 13/.02 · 300 RPM · 0.6–1.0 N·cm

Use P1 13/.02 to working length in continuous clockwise rotation. Apply minimal apical pressure. Withdraw periodically, clean and inspect the flutes, irrigate, and recapitulate as needed.

0 4 Progress through P2 and P3 as required 16/.02 → 19/.02 when clinically required

Use P2 16/.02 to working length. Use P3 19/.02 only when a larger expanded glide path is clinically required before shaping. Irrigate, clean the flutes, and recapitulate between instruments.

0 5 Reconfirm and transition to canal shaping ISO 015 confirmation · selected shaping system

Reconfirm working length with an ISO 015 K-file and an apex locator. Confirm patency, recapitulate and re-irrigate, then continue with the selected NiTi shaping system according to its current instructions for use.

Sterility & safety

Important information for this product version

Review the sterility, handling and safety information for this exact product version.

Sterility Non-sterile · sterilize before first use
Use Single use
Clinical handling & safety Review before clinical use
Before first clinical use
  • This product version is supplied non-sterile and must be sterilized before first clinical use.
  • Steam-autoclave at 134°C for 18 minutes using a validated process. Allow the instruments to dry completely before clinical use.
  • After clinical use, discard each file in an appropriate biohazard sharps container. Do not clean, disinfect, sterilize or reuse it.
  • For dental professional use only. Use rubber dam isolation and appropriate personal protective equipment.
  • Do not use in patients with known allergic sensitivity to nickel-titanium alloy or another device component.
  • Use only with a compatible torque-controlled endodontic motor in continuous clockwise rotation. Do not use in reciprocating motion.
  • Do not introduce PTF+ into an unscouted canal. Establish a smooth, reproducible manual glide path before mechanical preparation.
  • Use minimal apical pressure and never force the file. Withdraw, clean and inspect the flutes, irrigate and recapitulate if progression is not passive.
  • Do not use a file that is deformed, unwound, corroded, fractured or worn. Do not use mechanically where abrupt curvature or anatomy prevents safe passive progression.
Frequently asked questions

Common questions

Quick answers about product selection, configuration and clinical use.

Is NIC® PTF+ comparable to PathFile®?

NIC® PTF+ is positioned for a comparable three-file mechanical glide-path workflow and file sequence. It is an independent NIC® product and is not manufactured by, sponsored by, or affiliated with Dentsply Sirona.

When should NIC® PTF+ be introduced?

Use PTF+ after the canal has been manually scouted and a smooth, reproducible manual glide path has been established, and before canal shaping with the selected NiTi system.

What is the recommended PTF+ sequence?

Use PTF+ #1 / P1 13/.02 to working length, followed by PTF+ #2 / P2 16/.02. Use PTF+ #3 / P3 19/.02 when a larger expanded glide path is clinically required before shaping.

Is PTF+ #3 / P3 always required?

No. P3 19/.02 is used when a larger expanded glide path is clinically required before canal shaping.

What motor settings are recommended for PTF+?

Use a compatible torque-controlled endodontic motor in continuous clockwise rotation at 300 RPM and 0.6–1.0 N·cm. Confirm the motor and handpiece requirements before clinical use.

Can PTF+ be used in reciprocating motion?

No. PTF+ is intended for continuous clockwise rotary motion and should not be used in reciprocating motion.

Which PTF+ lengths are available?

PTF+ #1 / P1, PTF+ #2 / P2 and PTF+ #3 / P3 are available in 21 mm, 25 mm and 31 mm lengths.

Are NIC® PTF+ files supplied sterile?

No. This product version is supplied non-sterile and must be steam-sterilized before first clinical use at 134°C for 18 minutes using a validated process. Allow the instruments to dry completely before use.

Can NIC® PTF+ files be reused?

No. PTF+ files are single-use instruments. After clinical use, discard them in an appropriate biohazard sharps container.

What should I do if a PTF+ file does not progress easily?

Withdraw the file, clean and inspect the cutting flutes, irrigate, recapitulate with a manual file and re-irrigate. Do not force the file apically.

CanDent Group support

Need help choosing the right configuration?

CanDent Group can help you review the available configurations, specifications and product information for NIC® PTF+ Rotary Glide Path File before you place your order.

Product information: This page presents product specifications and workflow information for NIC® PTF+ Rotary Glide Path File from NIC® Dental . Always follow the current manufacturer instructions for use supplied with the exact product.